IOM-10, Engine Safety, Control and Alarm Systems
Instrumentation and Automation
Engine Safety, Control and Alarm Systems
IOM-10
Product Description
Control and data acquisition I/O modules for use with Wartsila engines in generating set and propulsion application mode., The Input / Output Module (IOM-10) is a modular, universal, configurable, microprocessor based data acquisition units developed to interface with the Wartsila main engine control system. The IOM-10 contains analogue and digital channels, mainly for data acquisition purposes and communicates via redundant CAN bus links. Each IOM contains 16 differential analogue inputs, 4 digital input/output channels, 2 frequency inputs, 2 analogue (4-20 mA) and 4 digital output (+24V reference and HSD) channels. The unit is designed for mounting directly on the engine. Supplies to the module are connected to dual redundant power sources.
Product Ratings
Power supplies: 18-32 VDC (Nominal: 24 VDC); | Operating temperature: -25 to 85 C; | Processor: Freescale MPC561, 56 Hz; | Memory: RAM/Flash 1MB typical; | Number of CAN Port: 2 (ISO 11898) |
Applicable Standards
Not Available / To be Updated