WARREN CAT A-30 bulkhead panel assembly, Equivalent Class A Divisions
fire Protection - Partitions & outfits
Equivalent Class A Divisions
WARREN CAT A-30 bulkhead panel assembly
Product Description
“Warren CAT A-30 Panel Assembly Bulkhead”
An asymmetric assembly composed of, seen from exposed side:
bent panels, insulation boards, stiffeners, tubes, hat channels, perforated plates, screws, ceramic tape and sealant. The assembly is held together with welds and screws and is sealed with intumescent firestop sealant between welds. Wall panels are welded to support channels on the unexposed side. The insulation material is sandwiched in place by the perforated plates, hat channels are stuffed with insulation to cover metal joints. Ceramic tape is used to prevent metal to metal contact.
List of components:
- Bent wall panels with/without ends consisting of 10-ga (3.4 mm) A1011 steel
- Square tubes, 4 x 4 x 120 in. with ¼ in. thickness (100 x 100 x 3048 mm with 0.64mm thickness) A500 steel
- Rock Wool Delta Marine Board insulation, 2 x 2 x 48 in. (50 mm x 50 mm x 1219 mm), 7pcf (112 kg/m3)
- Perforated plate, 1/8 in. (0.32 mm) round holes, 3/16 in. (0.48mm) staggered, 20-ga (0.911 mm) 316L stainless steel
- Hat channels, 20-ga (0.911 mm) 316L stainless steel
- Diverse stiffeners
- TEK screws ¼ in. Ø (0.64 mm) stainless steel
- Ceramic tape, GF08 produced by Gaskets, Inc. 2 and 4 in. (50 and 100 mm) wide with insulating ability up to 2300 °F (1260 °C)
- Firestop sealant (caulking)
Product Ratings
Not Available / To be Updated
Applicable Standards
Not Available / To be Updated