Product Description

The INSTRUMATIC MarineCEMS is a compact system design with extractive sampling using the Oxydan dilution probes in combination with an ambient UV-Fluorescent detection Sulfur Dioxide (SO2) instrument and a non dispersive infrared Carbon dioxide (CO2) analyzer/sensor. The Instrumatic Compact Marine CEMS solution also come with the option of nitrogen oxides (NOx) analyzer (NoxyTron). , , The Instrumatic MarineCEMS consists of two parts: , , 1 INSTRUMATIC OXYDAN DP7900:2017 Dilution probe with an optional NOx sensor connected via an umbilical cord to the a PLC enabling the system to monitoring NOx simultaneously., 2 INSTRUMATIC analyzer cabinet with an INSTRUMATIC T100 SO2/CO2 analyzer unit manufactured by Teledyne-API., The SO2 sensor is a gas phase UV-Fluorescent detection instrument that performs a continuous analysis of Sulphur dioxide., The CO2 sensor is a Non-Dispersive Infrared sensor measuring the CO2 concentration., The INSTRUMATIC MarineCEMS includes all necessary parts to sample, monitor and data log SO2/ CO2 & NOx exhaust gas emission.,

Product Ratings
Product Ratings

System Cabinet: | | Power supply: 240VAC 50Hz / 110VAC 60 Hz | Power Consumption: Max 350W, including DP7900 probe | Output: 4-20 mA | Protection class: IP54 | Temperature Range: 5 Deg C to +55 Deg C | Communication protocol: TCP/IP, Modbus TCP/IP, Modbus RTU | Air Supply: Min pressure 6kPA compressed air, non-condensing | Dimensions: 800 (H) mm x 600 (W) mm x 250 (D) mm | Weight: 50 kgs | | Probe: | Power supply: 240VAC 50Hz / 110VAC 60 Hz (via umbilical cord/cabinet) | Power Consumption: Max 300W | Protection class: IP65 (Junction Box) | Temperature Range: -10 Deg C to +85 Deg C | Dimensions: 300 (H) mm x 250 (W) mm x 500 (D) mm | Weight: 8 kgs | | SO2 Sensor: | Range: user selectable from 0 ppm to 2000 ppm (Standard setting: 0 ppm to 50 ppm - consult factory for higher range measurement accuracy) | Lower detection limit: 0.1 ppm | Lag time: < 10 sec. (from probe tip with 25 m of umbilical cord) | | CO2 Sensor: | Range: user selectable from 0 % to 20 % (Standard setting: 0 % to 12% - consult factory for higher range measurement accuracy) | Lower detection limit: 0.1 % | Lag time: < 10 sec. (from probe tip with 25 m of umbilical cord) | | NOx Sensor: | Range: user selectable from 0 ppm to 2000 ppm (Standard setting: 0 ppm to 1000 ppm - consult factory for higher range measurement accuracy) | Lower detection limit: 1 ppm | Lag time: < 5 sec.

Product Standards
Applicable Standards

IACS UR E10 (Rev. 6, Oct 2014).
Resolution MEPC. 259 (68) - Guidelines for Exhaust Gas Cleaning Systems (2015) Schemes A & B, SO2/CO2 ratio method for measurement of SOx emissions.
Resolution MEPC.177(58) (NOx Technical Code 2008) - sections 1.6.2 to 1.10 of Appendix 3.