Product Description
Product Description

“Autronica DCP Fixed System” A fixed installation based fire extinguishing system for use in gas fuel bunkering station areas. Main composition: A 2L/1.3 kg CO2 pilot gas cylinder fitted in a release cabinet connected with rubber hoses and SS tubing to a 40L/150 bar N2 cylinder that provides propellant gas via a pressure reducing valve (set point: 16 bar) and 15 mm SS tubing to a 200 kg dry chemical powder tank (safety valve set point: 16.5 bar). An automatically activated main valve (set point: 10 bar) on the powder tank feeds extinguishing powder through stainless steel distribution piping (DN50/40/25/20) to 8 pcs. 60°, ½” spiral jet nozzles.