Skip to main content

FRCmM, FRCmM-NA, FRCmM-NA-110, Rcd - Residual Current Devices

Product Category Icon
Product Category:
Miscellaneous Electric Control Components

Product type  Icon
Product Type:
RCD - Residual Current Devices

Product name
Product Name:
FRCmM, FRCmM-NA, FRCmM-NA-110
Product Description
Product Description

Residual Current Devices FRCmM Type AC, A, U and R
Operating characteristics Type A, AC acc. to IEC 61008
Type G, G/A acc. to ÖVE E 8601
Tripping class Instantaneous
Type G, R 10ms delay
Type S 40ms delay - with selective disconnecting function
Type U (only 30mA) 10ms delay
Type U (except 30mA) 40ms delay - with selective disconnecting function
Ratings (40°C)
Rated voltage (Un) 240/415V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Number of poles two / four pole
Rated current (In) 16, 25, 40, 63, 80, 100A
Rated tripping current (I?n) 30, 100, 300, 500mA
Sensitivity AC and pulsating DC
Rated short circuit capacity (ICN) 10kA with back-up fuse
Short circuit- / overload protection
Max. back-up fuse: In = 25A 25A gG/gL 25A gG/gL
Max. back-up fuse: In = 40A 40A gG/gL 40A gG/gL
Max. back-up fuse: In = 63A 63A gG/gL 63A gG/gL
Max. back-up fuse: In = 80A 80A gG/gL 80A gG/gL
Max. back-up fuse: In = 100A 100A gG/gL 80A gG/gL
Further technical ratings and type spectrum acc. manufacturer documentation.
Residual Current Devices FRCmM-NA Type A
Operating characteristics Type A acc. to IEC 61008
Type G, G/A acc. to ÖVE E 8601
Tripping class Instantaneous
Type G 10ms delay at 50Hz
Ratings (40°C)
Rated voltage (Un) 240/415V AC, 50/60Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Number of poles two / four pole
Rated current (In) 25, 40, 63A
Rated tripping current (I?n) 30, 300mA
Sensitivity AC and pulsating DC
Rated short circuit capacity (ICN) 10kA with back-up fuse
Short circuit- / overload protection
Max. back-up fuse: In = 25A 63A gG/gL 25A gG/gL
Max. back-up fuse: In = 40A 63A gG/gL 40A gG/gL
Max. back-up fuse: In = 63A 63A gG/gL 40A gG/gL
Residual Current Devices FRCmM-NA-110 Type A
Operating characteristics Type A acc. to IEC 61008
Type G, G/A acc. to ÖVE E 8601
Tripping class Instantaneous
Type G 10ms delay at 50HZ
Ratings (40°C)
Rated voltage (Un) 110/190V AC, 50/60Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Number of poles two / four pole
Rated current (In) 25, 40, 63A
Rated tripping current (I?n) 30, 300mA
Sensitivity AC and pulsating DC
Rated short circuit capacity (ICN) 10kA with back-up fuse
Short circuit- / overload protection
Max. back-up fuse: In = 25A 63A gG/gL 25A gG/gL
Max. back-up fuse: In = 40A 63A gG/gL 40A gG/gL
Max. back-up fuse: In = 63A 63A gG/gL 40A gG/gL
Further technical ratings and type spectrum acc. manufacturer documentation.

Product Ratings
Product Ratings

Not Available / To be Updated

Product Standards
Applicable Standards

Not Available / To be Updated