Combined RCD/MCB Devices FRBdM, FRBmM, FRBm4, FRBm6, NmRBM, …

Product Category Icon
Product Category:
Miscellaneous Electric Control Components

Product type  Icon
Product Type:
RCD - Residual Current Devices

Product name
Product Name:
Combined RCD/MCB Devices FRBdM, FRBmM, FRBm4, FRBm6, NmRBM, NmRB4, NmRB6
Product Description
Product Description

Combined RCD/MCB Devices FRBdM, 1+N-, 2-poles Type A Digital
Operating characteristics Type A acc. to IEC 61009
Type G acc. to ÖVE E 8601
Tripping line voltage-independent
Type G 10 ms delay 3kA (8/20?s), surge current-proof
Ratings (40°C)
Rated voltage (Un) 240V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Rated current (In) 6 - 25A
Rated tripping current (I?n) 10, 30, 100 mA
Characteristic B, C, D
Sensitivity AC and pulsating DC
Rated breaking capacity (Icn) 10kA
Max. back-up fuse (short circuit) 100A gL (>10kA)
Combined RCD/MCB Devices FRBmM, 1+N-pole
Operating characteristics Type A, AC acc. to IEC 61009
Type G acc. to ÖVE E 8601
Tripping line voltage-independent instantaneous 250A (8/20?s), surge current-proof
Type G 10 ms delay 3kA (8/20?s), surge current-proof
Ratings (40°C)
Rated voltage (Un) 240V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Rated current (In) 2 - 40A
Rated tripping current (I?n) 10, 30, 100, 300 mA
Characteristic B, C, D
Sensitivity AC and pulsating DC
Rated breaking capacity (Icn) 10kA
Max. back-up fuse (short circuit) 100A gL (>10kA)
Combined RCD/MCB Devices FRBmM, FRBm6, 2-pole, Type AC, A
Operating characteristics Type A, AC acc. to IEC 61009
Tripping line voltage-independent instantaneous 250A (8/20?s), surge current-proof
Type Super A 10 ms delay, surge current-proof
Ratings (40°C)
Rated voltage (Un) 240V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Rated current (In) 6 - 40A
Rated tripping current (I?n) 30, 100, 300 mA
Characteristic B, C
Sensitivity AC and pulsating DC
Rated breaking capacity (Icn)
FRBmM 10kA
FRBm6 6kA
Max. back-up fuse (short circuit) 100A gL (>10kA)
Combined RCD/MCB Devices FRBmM, 3-pole, Type A
Operating characteristics Type A acc. to IEC 61009
Type G acc. to ÖVE E 8601
Tripping line voltage-independent instantaneous 250A (8/20?s), surge current-proof
Type G 10 ms delay, surge current-proof
Ratings (40°C)
Rated voltage (Un) 240/415V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Rated current (In) 6 - 32A
Rated tripping current (I?n) 30, 100 mA
Characteristic B, C, D
Sensitivity AC and pulsating DC
Rated breaking capacity (Icn) 10kA
Max. back-up fuse (short circuit) 100A gL (>10kA)
Combined RCD/MCB Devices FRBm6, FRBm4, 3+N-pole, Type AC and A
Operating characteristics Type A, AC acc. to IEC 61009
Tripping line voltage-independent instantaneous 250A (8/20?s), surge current-proof
N protected.
Ratings (40°C)
Rated voltage (Un) 240/415V AC, 50Hz
Rated impule withstand voltage (Uimp) 4kV
Rated insulation voltage (Ui) 440V
Rated current (In) 6 - 32A
Rated tripping current (I?n) 30, 100, 300 mA
Characteristic B, C, D
Sensitivity AC and pulsating DC
Rated breaking capacity (Icn)
FRBm4 4,5kA
FRBm6 6kA
Max. back-up fuse (short circuit) 100A gL (>10kA)
Further technical ratings and type spectrum acc. manufacturer documentation.