Skip to main content

FDO221, FDOOT221, FDO241, FDOOT241-A9, FDOOT241-A9-Ex, OP720…

Product Category Icon
Product Category:
Fire Detection and Alarm System

Product type  Icon
Product Type:
Fixed Fire Detection and Alarm Systems Components - Smoke Detectors

Product name
Product Name:
FDO221, FDOOT221, FDO241, FDOOT241-A9, FDOOT241-A9-Ex, OP720, OOH740, OOH740-A9-Ex, OH720
Product Description
Product Description

Smoke detectors
· FDO221 Smoke Detector with Short-Circuit Isolator
· FDOOT221 Multisensor Detector (Point detector with two additional heat sensors) with Short-Circuit Isolator
· FDO241 Smoke Detector with Short-Circuit Isolator
· FDOOT241-9 Multisensor Detector (Point detector with two additional heat sensors) with Short-Circuit Isolator
o Compatible Base Adapter: FDB299; FDB241
o Compatible Base Attachment: FDB291
o Compatible Base Attachment Wet: FDB295
o Compatible Base Attachment Wet with Sealing: FDB293
o Compatible Detector Base Addressable: FDB221; FDB222
o Can be used addressed on the FD- Net of Sinteso® fire control panels FC2020-AA ;
FC2020- AE; FC2040-AA; FC2040-AE.
· FDOOT241-A9 Multisensor Detector (Point detector with two additional heat sensors) with Short-Circuit Isolator
o Compatible Base Adapter: FDB299; FDB241
o Compatible Base Attachment: FDB291
o Compatible Base Attachment Wet: FDB295
o Compatible Base Attachment Wet with Sealing: FDB293
o Compatible Detector Base Addressable: FDB221; FDB222; SPF600
o Compatible Detector Base Collective: FDB201; FDB202; DB1101A
o Can be used addressed on the FD-Net of Sinteso® fire control panels FC2020-AA ; FC2020- AE; FC2040-AA; FC2040-AE.
· FDOOT241-A9-Ex Multisensor Detector Ex (Point detector with two additional heat sensors) with Short-Circuit Isolator
o Compatible Base Attachment: FDB291
o Compatible Base Attachment Wet with Sealing: FDB293; FDB295
o Compatible Detector Base Addressable: FDB221; FDB222
o Compatible Detector Base Collective: FDB201; FDB202
o The Safety barrier SB3 shunt Zener diode barrier and the safety barrier FDCL 221-EX are used as an interface between explosion-hazard and non-hazardous areas. The Ex approval is not integral part of this certificate; see BVS 12 ATEX E 087 X and BVS 12 ATEX E 094.
o Can be used addressed on the FD-Net of Sinteso® fire control panels FC2020-AA; FC2020-AE; FC2040-AA; FC2040-AE and collective on the AlgoRex® CS1140 MED.
· OP720 Smoke Detector
o Compatible Base Attachment: BA720
o Compatible Base Attachment Wet: BA721
o Compatible Detector Base Addressable: DB720; DB721; DB722
o Compatible Base Attachment / Base Seal: BA720/RS720
o Can be used addressed on the CNET of CerberusPRO® fire control panels FC722-ZA;
FC722-ZE; FC724-ZA; FC724-ZE.
· OOH740-A9-Ex Multisensor Detector Ex (Point detector with two additional heat sensors)
o Compatible Base Attachment Wet: FDB295
o Compatible Base Attachment Wet with Sealing: FDB293
o Compatible Detector Base Addressable: FDB221;FDB222
o Compatible Detector Base Collective: FDB201; FDB202
o The Safety barrier SB3 shunt Zener diode barrier and the safety barrier FDCL 221-EX are used as an interface between explosion-hazard and non-hazardous areas. The Ex approval is not integral part of this certificate; see BVS 12 ATEX E 087 X and BVS 12 ATEX E 094.
o Can be used addressed on the CNET of CerberusPRO® fire control panels FC722-ZA ; FC722-ZE; FC724-ZA; FC724-ZE and collective on the AlgoRex® CS1140 MED.
· OOH740 Multisensor Detector (Point detector with two additional heat sensors)
o Compatible Base Attachment: BA720
o Compatible Base Attachment Wet: BA721
o Compatible Base Attachment / Base Seal: BA720/RS720
o Compatible Detector Base Addressable: DB720; DB721; DB722
o Can be used addressed on the CNET of CerberusPRO® fire control panels FC722-ZA; FC722-ZE; FC724-ZA; FC724-ZE.
· OH720 Multisensor Detector (Point detector with two additional heat sensors)
o Compatible Base Attachment: BA720
o Compatible Base Attachment Wet: BA721
o Compatible Base Attachment / Base Seal: BA720/RS720
o Compatible Detector Base Addressable: DB720; DB721; DB722
o Can be used addressed on the CNET of CerberusPRO® fire control panels FC722-ZA; FC722-ZE; FC724-ZA; FC724-ZE
· DO1101A-Ex Smoke Detector
o Compatible Detector Base Collective: DB11xx
o The Safety barrier SB3 shunt Zener diode barrier is used as an interface between explosion-hazard and
o non-hazardous areas. The Ex approval is not integral part of this certificate, see PTB 02 ATEX 2135.
o Can be used addressed on the FD-Net of AlgoRex® CS1140 MED fire control panels
· DOT1151A-Ex Multisensor Detector (Point detector with additional heat sensor)
o Compatible Detector Base Collective: DB11xx
o The Safety barrier SB3 shunt Zener diode barrier is used as an interface between explosion-hazard and non-hazardous areas. The Ex approval is not integral part of this
certificate, see PTB 02 ATEX 2098.
o For use on the addressable: FD-Net of AlgoRex® CS1140 MED fire control panels

Product Ratings
Product Ratings

Not Available / To be Updated

Product Standards
Applicable Standards

Not Available / To be Updated

Similar Products