XY08-JK, Alarm and Monitoring System Components
Instrumentation and Automation
Alarm and Monitoring System Components
XY08-JK
Product Description
The Alarm and Monitoring System is designed for monitoring the parameters, command and alarm record of the main engine, auxiliary engine and other accessory machinery in engine room. , The system is mainly composed of user interface system, extension alarm panel, AMS printer, data acquisition, communication network and engineer safety alarm system. , , Detail components are listed below:, - Digital input main module: XY080112-M, - Digital input extension module: XY080112-S, - 4-20mA analogue input module: XY080113, - PT100 input module: XY080115, - Thermocouple input module: XY080116, - Digital output main module: XY080117-M, - Digital output extension module: XY080117-S, - 4-20mA analogue output module: XY080118, - Extension alarm panel: XY080122, - LCD display: HP Elite Display E190i 19-inch, - Industrial personal computer: HP 800 G3 , - UPS Power supply: APC SUA1000ICH, - Switch: EKI-2525, - AC/DC Power Supply: 6EP33336SB000AY0, - Printer etc., , Software for XY08-JK system, revision 1.1.
Product Ratings
Supply voltage: 230V AC/24V DC. | For rating of hardware component,
Applicable Standards
IEC 60945: 2002
IACS E10: 2014