Skip to main content

Vapor Pressure & Gas Monitoring System, MODEL:VGMS

Product Category Icon
Product Category:
Instrumentation and Automation

Product type  Icon
Product Type:
Vapour Alarm System

Product name
Product Name:
Vapor Pressure & Gas Monitoring System, MODEL:VGMS
Product Description
Product Description

This system consists of the following components;, , 1. Alarm & Display Panel located in the Room (Safety Area), - Alarm & Display Monitor Panel (Model:SMART PA-1300), - I.S Barrier (Model: D1014D), , 2. Detection Cabinet located in the Weather Deck (Hazardous Area), - Oxygen Gas Detector (Model: Xgard Type 1, (Model:GTD-2000 Tx), - Pressure Transmitter (Model: Level 3000), , 3. Gas Detector located in the Pump Room (Hazardous Area), - Oxygen Gas Detector (Model: Xgard Type 2), - Flammable Gas Detector (Model: Xgard Type 5), , For more detail, refer to manufacturer's catalogue.

Product Ratings
Product Ratings

1. Alarm & Display Monitor Panel (Model: SMART PA-1300): | -Power supply input : 220VAC and 24VDC (Alarm & Display Monitor) | -Input : 4~20mA, 8CH. | Digital Input(Dry Contact) 2 channel | -Accuracy: +/- 0.1 % F.S | | 2. Oxygen Gas Detector (Model: Xgard Type 1): | -Operating Voltage: 8 ~ 30 Vdc | -Output Signal: 4 ~ 20 mA | -Measuring Range: 0 ~ 25% Vol. | -Fault Signal: < 3Ma | -Enclosure: EEx ia IIC T6 T4 Ga, Ex-Certification: Baseefa ATEX 0115 | | 3. Pressure Transmittal (Model: Level 3000): | -Output Signal: 4 ~ 20 mA | -Accuracy: </- 0.25 % F.S | -Thermal Shift: Zero </- +/- 0.08 % F.S, -25 ~ 85 Degree C | Span </- +/- 0.02 % F.S, -25 ~ 85 Degree C | -Measurement Range: -1 ~ 0.6 Bar | -Enclosure: EEx ia IIC Ex-Certification: KRH 18 ATEX 1005X | | 4. Oxygen Gas Detector (Model: GTD-2000 Tx): | -Operating Power: 18 ~ 31 Vdc / 200 mA Max | -Measuring Range: % Vol. | -Operation Humidity: 5 ~ 99% RH | -Enclosure: Exd IIC T4~T6, Ex-Certification: SIRA 08 ATEX1003 | | 5. Oxygen Gas Detector (Model: Xgard Type 2): | -Operating Voltage: 8 ~ 30 Vdc -Output Signal: 4~ 20 Ma | -Measuring Range: 0 ~ 25% Vol. | -Fault Signal: < 3Ma -Enclosure: EExd IIC Ex-Certification: Basefa ATEX 0024X | | 6. Flammable Gas Detector (Model:Xgard Type 5): | -Operating Voltage: 10 ~ 30 Vdc -Output Signal: 4 ~ 20 mA | -Measuring Range: 0 ~ 100% LEL. | -Fault Signal: < 3mA -Enclosure: EExd IIC Ex-Certification: Basefa ATEX 0024X | | 7. I.S Barrier (Model: D1014D): Ex-Certification - DMT 01 ATEX E 042X | | 8. Oxygen Gas Detector (Model: GTD-2000 Tx): | -Operating Voltage: 18-31 VDC | -Output Signal: 4 ~ 20 mA | -Measuring Range: 0 ~ 25% Vol. | -Max power consumption: Max 6 Watts. At 24Vdc | -Current output: 4-20mA (Source or Sink) | -Operating Temperature: -40 deg.C ~ 80 deg.C | -IP rating: IP66/67 | -Enclosure: Ex D IIC T4~T6, Ex-Certification: Sira 08ATEX1003

Product Standards
Applicable Standards

IACS UR E10 Rev.7 (2018 edition)
IEC 60092-504 (2016 edition)
IEC 60068-1 (2013 edition)

Similar Products