SITRANS LC 300 and Pointek CLS300, Liquid Level Gauges and Indicators
Instrumentation and Automation
Liquid Level Gauges and Indicators
SITRANS LC 300 and Pointek CLS300
Product Description
The CLS300 and LC300 are level measurement based on capacitance principle with all electronic components located on an aluminium coated enclosure on the top end of the assembly, which is situated above the tank deck and a PFA coated electrode contained inside a stilling well.
Product Ratings
SITRANS LC 300 | Power: 12 to 30 Vdc any Polarity, 2-Wire current Loop Circuit; | Output: 4-20 mA; | Measuring Range: 25 m (82 ft) | Ambient Temperature: -40C to 70C (-40F to 158F) ; | Hazardous Locations: | CSA & FM Class I, Div.1, Groups A, B,C & D; | CSA & FM Class II, Div.1, Groups E, F & G; | CSA & FM Class III; | KEMA ATEX II 1/2 G EEx d [ia] IIC T6-T1 | KEMA ATEX II 1G EEx ia IIC T6-T4 | Enclosure: Type 4/NEMA 4/IP65, IP68 | POINTEK CLS300 | Power: 12 to 250 Vac/dc (Standard Version) | 12 to 30 Vdc (Profibus Version) | Measuring Range: 25 m (82 ft) | Ambient Temperature: -40C to 70C (-40F to 158F) ; | Hazardous Locations: | CSA & FM Class I, Div.1, Groups A, B,C & D; | CSA & FM Class II, Div.1, Groups E, F & G; | CSA & FM Class III; | KEMA ATEX II 1/2 G EEx d [ia] IIC T6-T1 | KEMA ATEX II 1G EEx ia IIC T6-T4; | Enclosure: Type 4/NEMA 4/IP65, IP68 (Optional) |
Applicable Standards
IMO MSC 145(77) and IACS UI SC 180; EN 61326-1:2006; CISPR 11:2004/EN55011;2007; EN 61326-1:2006;
CAN/CSA C22.2