Skip to main content

Salwico CCP with appellation: Cargo, Ro/Pax, Workboat, Yacht…

Product Category Icon
Product Category:
Fire Detection and Alarm System

Product type  Icon
Product Type:
Fire Detection and Fire Alarm Systems

Product name
Product Name:
Salwico CCP with appellation: Cargo, Ro/Pax, Workboat, Yacht and Cruise;
, Models: CFD500, CFD500N and CFD5000
Product Description
Product Description

The Salwico CCP System is a multi loop analogue addressable fire control, fire alarm & general alarm system., The Salwice CCP comprises: , Control Panel M 4.3, Control/Repeater M 4.3, Repeater M 4.3, Control M X, Bus Isolator M H (single/double Module), Loop M X, I/O M70, I/O M700, Relay M 8, Bus Con M 10/20, Change Over M X, Charger M, PSU M AC/DC 5 A, General alarm push button NS-GA2, NS-GA2/IP55, CS-Loop M, CS-Safety M, CM-L-F, QUINT-PS/24DC/24DC/5, Change Over M Ext H, Surge Prot M H, MUX M 16, ST Interface M H

Product Ratings
Product Ratings

Control Panel M 4.3, Control/Repeater M 4.3 | Operating voltage 19-30 V DC; operating temperature -5 to +55 C degrees, IP 22. | Repeater M 4.3: operating voltage 19-30 V DC, operating temperature -5 to +55 C degrees, IP 55 | Control M X, Bus Isolator M H (single/double Module), Loop M X, I/O M70, I/O M700, Relay M 8, Bus Con M 10/20 | Operating voltage 19-30 V DC; operating temperature -5 to +55 C degrees | Change Over M X: 85-264 V AC, Output: 15-30 V DC | Charger M: 28 VDC | PSU M AC/DC 5 A: 85-264 V AC (45-65 Hz), 90-350 V DC | NS-GA2: 20-38 VDC, IP 22 or IP55. | QUINT-PS/24DC/24DC/5: 18-32 V DC Output 18-32V DC; | operating temperature -25 to +70 C degrees. | CS-Loop M, CM-L-F, CS-Safety M : operating voltage 19-30 VDC; | Operating temperature -40 to +70 C degrees. | Change Over M Ext H, Surge Prot M H, MUX M 16, ST Interface M H | Operating voltage 19-30 VDC; Operating temperature -5 to +55 C degrees

Product Standards
Applicable Standards

SOLAS Chapter II-2 Regulation 3/22, Consolidated Edition 2014 and IMO FSS Code 2007 (supplement 2014) Chapter 9/ 2.1.1; 2.1.2; 2.1.3; 2.1.5; 2.1.6; 2.3.2; 2.5
IEC 60533 (2015);
IEC 60092-504 (2016);
IACS E10 Rev 7:2018

EN 54-2 (1997) + A1 (2002);
EN 54-4 (1997) + A1 (2002) + A2 (2006);