H-120 and H-60 Decks & Bulkheads with Cable Transit Model CF…
Electric Cables and Accessories
<p>Shipboard Electric Cables and Accessories</p> /url1
Deck and Bulkheads, Watertight Seals, Pipes and Cables
H-120 and H-60 Decks & Bulkheads with Cable Transit Model CFS-T SS, CFS-T SSF, CFS-T RR.
Product Description
Modular cable transit system consisting of steel frames or plugs in combination with insert blocks, made of halogen-free elastomeric rubber (standard and EMC), as well as compression units and anchor plates.
Product Ratings
H-120, H-60, Model SS-4x1 tested water / gas tight at a pressure of 2 bar (OFI 47299-e of 04 June 2002). | Model SS-2x1 tested water tight at a pressure of 11 bar and gas tight at a pressure of 7 bar (OFI 47299/3-e of 30 July 2002). | Filler module 60/0 tested for short term chemical resistance to natural gasoline, acc. to ISO 37 and for air tightness (0.5 bar, 10 min.) after storage at -60C for four days (OFI 305.063 and OFI 305.027 of 16 August 2005).
Applicable Standards
- IMO Resolution A.754(18) as adopted 4 Nov 1993 with temperature/time curve specified by United Kingdom's Department of Energy & Norwegian Petroleum Directorate as being typical fire for hydrocarbon nature.
- SOLAS (Consolidated Edition 2014) Reg. II-2/9.3.1 and 2010 FTP Code (Edition 2012).
Guidance as per UK Department of Energy / Fire Research Station document "The Hydrocarbon Fire Resistance Test for Elements of Construction for Offshore Installations (Test Specification - Issue 1: January 1990)".