Flex 5000 Product Family, Computers and Programmable Logic Controllers
Instrumentation and Automation
Computers and Programmable Logic Controllers
Flex 5000 Product Family
Product Description
Flex 5000 product family which includes the following:, - EtherNet/IP Adapters: 5094-AENTR, 5094-AEN2TR, 5094-AENSFPR, 5094-AEN2SFPR, 5094-AENTRXT, 5094-AEN2TRXT, 5094-AENSFPRXT, 5094-AEN2SFPRXT, - High-speed Counter I/O: 5094-HSC, 5094-HSCXT, - Safety Digital Input I/O: 5094-IB16S, 5094-IB16SXT, - Safety Digital Output I/O: 5094-OB16S, 5094-OB16SXT, - Safety Relay Output I/O: 5094-OW4IS, 5094-OW4ISXT, - Analog Isolated HART Input I/O: 5094-IF8IH, 5094-IF8IHXT , - Analog Isolated HART Output I/O: 5094-OF8IH, 5094-OF8IHXT , - Interconnect Cables: 5094-CE30, 5094-CE10, 5094-CE05, - Terminal Bases (comprises of Removable Terminal Block and Mounting Base): 5094-TB3, 5094-TB3S, 5094-TB3T, 5094-TB3TS, 5094-TB3W, 5094-TB3WS, 5094-TB3XT, 5094-TB3SXT, 5094-TB3TXT, 5094-TB3TSXT, 5094-TB3WXT, 5094-TB3WSXT, 5094-TB3I, 5094-TB3IS, 5094-TB3IXT, 5094-TB3ISXT, 5094-TB32V, 5094- TB32VS, 5094-TB32C, 5094-TB32CS, 5094-TB3AC, 5094-TB3ACS, 5094-TB32VXT, 5094-TB32VSXT, 5094- TB32CXT, 5094-TB32CSXT, 5094-TB3ACXT, 5094-TB3ACSXT, - Mounting Bases (common for all Terminal Base): 5094-MB, 5094-MBXT, - Removable Terminal Blocks: 5094-RTB3, 5094-RTB3S, 5094-RTB3T, 5094-RTB3TS, 5094-RTB3W, 5094-RTB3WS, 5094-RTB3XT, 5094-RTB3SXT, 5094-RTB3TXT, 5094-RTB3TSXT, 5094-RTB3WXT, 5094-RTB3WSXT, 5094-RTB3I, 5094-RTB3IS, 5094-RTB3IXT, 5094-RTB3ISXT, 5094-RTB32V, 5094- RTB32VS, 5094-RTB32C, 5094-RTB32CS, 5094-RTB3AC, 5094-RTB3ACS, 5094-RTB32VXT, 5094- RTB32VSXT, 5094-RTB32CXT, 5094-RTB32CSXT, 5094-RTB3ACXT, 5094-RTB3ACSXT, , Notes:, 1. Adapters with the number "2" in the suffix supports 16 I/Os, while adapter without the number "2" supports 8 I/Os., 2. Suffix "XT" denotes extended temperature version, suffix "S" denotes Spring type, suffix "T" denotes CJC type, suffix "W" denotes Relay type.
Product Ratings
EtherNet/IP Adapters Supporting 8 I/Os: Main power: 1.25A @ 18-32 VDC; Backplane Power: 1.13A @ 15VDC | EtherNet/IP Adapters Supporting 16 I/Os: Main power: 1.88A @ 18-32 VDC; Backplane Power: 1.8A @ 15VDC | | High Speed Counter I/O: Max Sensor Actuator Power (SA): 3A @ 18-32VDC, Max Input (IN): 8mA @ 18-32VDC per channel, Max Output(OUT): 1A @ 18-32VDC per channel | | Safety Digital Input I/O: Max Sensor Actuator Power (SA): 1.8A @ 18-32VDC, Max Input (IN): 2.5mA @ 10-32VDC per channel, Test Output (TO): 200mA @ 18-32VDC per channel | | Safety Digital Output I/O: Max Sensor Actuator Power (SA): 8.2A @ 18-32VDC, Max Output (OUT): 0.5A @ 18-32VDC per channel | | Safety Relay Output I/O: Max Sensor Actuator Power (SA): 125mA @ 18-32VDC, Max Output (OUT): 2A @ 5-30VDC per channel, Max Output (OUT): 2A @ 125/240VAC per channel | | Analog Isolated HART Input I/O: Input Rating (IN): 4-20mA @ 10VDC per channel, SSV Rating: 20mA @25VDC per channel, Sensor Actuator Power (SA): 350mA @18-32VDC, Backplane Power (BP): 35mA @15VDC | | Analog Isolated HART Output I/O: Output Rating (OUT): 4-20mA @ 10VDC per channel, Sensor Actuator Power (SA): 240mA @18-32VDC, Backplane Power (BP): 35mA @15VDC | | Interconnect Cables: Backplane Power (BP): 1.8A @15VDC | | Terminal Base: SA: 10A@18-32VDC, IN/OUT:2A @ 32VDC | CJC Terminal Base: SA:10A @18-32VDC, IN :100mA @ 10VDC, Sensor Source Voltage Output (SSV): 1.8A @24VDC | Terminal Base-Relay: SA:10A @18-32VDC, OUT: 2A @ 125VDC / 2A @ 240VAC 50/60Hz | Terminal Base-32 point Input: SA: 10A@18-32VDC, IN/OUT:2A @ 32VDC | Terminal Base-32 point Output: SA: 10A@18-32VDC, IN/OUT:2A @ 32VDC | Terminal Base-AC: SA:10A @240VAC 50/60Hz, IN/OUT: 2A @ 240VAC 50/60Hz | | Mounting Base: Backplane Power: 100mA @ 15V DC, Backplane Power (Vcc): 15 mA @ 3.3V | | Removable Terminal Blocks: SA:10A@18-32VDC, IN/OUT:2A @ 32VDC | CJC-Removable Terminal Block: SA:10A @18-32VDC, IN :100mA @ 10VDC, SSV: 1.8A @24VDC | Removal Terminal Block-Relay: SA:10A @18-32VDC, OUT: 2A @ 125VDC / 2A @ 240VAC 50/60Hz | Removal Terminal Block-32 point Input: SA: 10A@18-32VDC, IN/OUT:2A @ 32VDC | Removal Terminal Block-32 point Output: SA: 10A@18-32VDC, IN/OUT:2A @ 32VDC | Removal Terminal Block-AC: SA:10A @240VAC 50/60Hz, IN/OUT: 2A @ 240VAC 50/60Hz | | Hazardous Locations: Class I, Division 2
Applicable Standards
EU Mutual Recognition Technical Requirements for Computers and Programmable logic Controllers (PLCS) Version 0.3, 01 April 2016