Gland Accessories of Certified-Safe Type, Model A2FRC for conduit, Adaptors, Reducers and Stopping Plugs as certified by a recognized testing laboratory. They can be used in both hazardous and/or non-hazardous locations on ships and offshore units., , A2FRC range of cable glands , For termination of circular braided or unarmoured cables. Consisting of a male-threaded entry item, seal actuation nut and outer captivated or running coupling. Front entry item, with a displacement sealing ring screws into an enclosure entry. The outer running coupling retained in the seal actuation nut allowing a free running threaded connection., , Ranges of Adaptors, Reducers and Stopping Plugs, 737: Adaptor/reducer , 787: 90 degree Adaptor , 797: Adaptor , 777: Insulated Adaptor , 747, 757, 767: Stopping Plugs , 783, 793: Y adaptor, T adaptor, , Types 737 and 797 Ranges of Adaptors and Reducers: , Metallic or non-metallic 737 Range of Adaptors / Reducers for conversion to another thread form and/or size. 797 Range of Adaptors intended to convert an enclosure entry to the opposite thread form and/or size. May have an optional O-ring seal. , , Types 747, 757 and 767 Ranges of Stopping Plugs, Type 747 Range of Stopping Plugs manufactured from metallic or non-metallic material comprising a cylindrical body with an external male thread. Having a socket head recess (747), hexagonal head (757) or domed head (767). May have an optional 'O' ring seal., , Type 777 Range of insulated adaptors , Consist of three parts: a metallic front portion that forms a threaded entry into the equipment, a non-metallic insulator and a metallic rear section that accommodates a gland. , , Type 787 Range of Right-Angled Adaptors, Have a male thread at one end, a female thread at 90 to the male thread. Intended to provide cable entry options where space is limited. May have an optional O-ring seal. , , Type 783 series (Y) and 793 series (T) shaped dual entry angled Adaptors. Having a male thread at one end and two female threads 120 and 90 respectively to the male thread. Intended to provide dual cable entry options for cables to enter enclosures where space is limited. May have an optional O-ring seal.,

Product Ratings
Product Ratings

A2FRC: range of cable glands | Ingress protection: IP 66 | Temperature: -60 C to +130 C (standard seal), -20 C to +200 C (high temperature seal) | Type of Protection: Flameproof, Increased Safety, Restricted Breathing and Dust Protection | Marking: Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da, Ex nR IIIC Da; IEC Ex Certificate: IECEx SIR13.0023X Issue 3 | : II 2G Ex d IIC Gb, II 2G Ex e IIC Gb, II 1D Ex ta IIIC Da, II 3 Ex nR IIC Gc; ATEX Certificate: SIRA 13ATEX1068X, SIRA 13ATEX4074X | | 737, 747, 757, 767, 797 | Ingress protection: IP 64 | Temperature: Non-Metallic (737,747, 757, 767): -20 C to +60 C, Metallic:-60 C to +20 C | Type of Protection: Flameproof, Increased Safety and Dust | Marking: Ex d IIC Gb/ Ex e IIC Gb, II 1D Ex ta IIIC Da (Metallic Version) | : Ex e IIC Gb, Ex ta IIIC Da (Non-metallic Version) | Marking: II 2G Ex d IIC Gb/ Ex e IIC Gb, II 1D Ex ta IIIC Da (Metallic Version) | : II 2 G Ex e IIC Gb, II 1D Ex ta IIIC Da (Non-metallic Version) | IEC Ex Certificate: IECEx SIR 13.0094X Issue 1, ATEX Certificate: SIRA 13ATEX1265X | | 777 | Ingress protection: IP 66 | Temperature: -60 C to +130 C | Type of Protection: Flameproof, Increased Safety and Dust | Marking: Ex d IIC Gb/ Ex e IIC Gb/ Ex ta IIIC Da; IECEx Certificate: IECEx SIR 10.0027U Issue 0 | : II 2GD Ex d IIC Gb / Ex e IIC Gb / Ex ta IIIC Da; ATEX Certificate: Sira 10ATEX1057U Issue: 0 | | 787 | Ingress protection: IP 64 | Temperature: -60 C to +200 C | Type of Protection: Flameproof, Increased Safety and Dust | Marking: Ex d IIC Gb / Ex e IIC Gb, Ex ta IIIC Da; IECEx Certificate: IECEx SIR 14.0014U Issue 0 | : II 2 G II 1 D, Ex e IIC Gb/ Ex d IIC Gb/ Ex ta IIIC Da; ATEX Certificate: Sira 14ATEX1033U Issue 0 | | | 783, 793 | Ingress protection: IP 64 | Temperature: -60 C to +200 C | Type of Protection: Flameproof, Increased Safety, Restricted Breathing and Dust Protection | Marking: Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da; IEC Ex Certificate: IECEx SIR IECEx SIR 16.0081U Issue 1 | : II 1D 2G Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da; ATEX Certificate: Sira 16ATEX1234U Issue 1 |

Product Standards
Applicable Standards

A2FRC, 737, 787, 797, 777, 747, 757, 767
IEC 60079-0 Ed 6.0:2011, IEC 60079-1 Ed 6.0:2007, IEC 60079-7 Ed 4.0:2006, IEC 60079-15 Ed 4.0:2010, IEC 60079-31 Ed 1.0:2008, IEC 62444 Ed 1.0:2010
EN 60079-0:2012, EN 60079-1:2007, EN 60079-7:2007, EN 60079-15:2010, EN 60079-31:2009, BS 6121:1989, EN 50262:1998 + Amendment 2001, EN 62444:2013

783, 793: Y adaptor, T adaptor
IEC/EN 60079-0 Ed 6.0:2011, IEC/EN 60079-1 Ed 7.0:2014, IEC/EN 60079-7 Ed 5.0:2015, IEC/EN 60079-31 Ed 2.0:2013
EN 60079-0:2012/A11:2013, EN 60079-1:2014, EN 60079-7:2015, EN 60079-31:2014