The TraceNet ECM (Electronic Control Module) is an electronic temperature control and monitoring module specifically designed for controlling heat tracing circuits used in freeze protection and temperature maintenance applications. ECM may also be used as a combination temperature controller with either low or high temperature alarm or a temperature limiter.
Product Ratings
Normal Operating/Control Voltage 12/208/240 VAC (50/60Hz) | Operating Ambient Storage Range: -76 deg. F to 131 deg. F (-60 deg. C to 55 deg. C) | Minimum Ambient Temperature: -100 deg. F (-74 deg. C) | Control Capacity: One Heat Tracing Circuit | Temperature Inputs: One or Two 3 wire 100 Ohm @ 32 deg. F (0 deg. C) | Temperature Control Range: 32 deg. F to 932 deg. F (0 deg. C to 500 deg. C) | Temperature Measurement Range: -76 deg. F to 932 deg. F (-60 deg. C to 500 deg. C) | Alarm Relay Current Ratings: 2 Amps | Alarm Relay Contact Voltage Ratings: 120/208/230/240 VAC | | Hazardous Locations rating in Canada (all constructions except mounting option OS) | Class I Div. 2 Groups A , B, C, D, Class II Div. 2 Groups F, G, Class III, T4 | Ex eb mb [ib] IIC T4; Ex tb IIIC T135 deg. C | | Hazardous Locations rating in U.S.A (all constructions except mounting option OS) | Class I Div. 2 Groups A , B, C, D, Class II Div. 2 Groups F, G, Class III, T4 | Class I, Zone I, AEx eb mb [ib] IIC T4; Zone 21 AEx tb IIIC T135 deg. C | | Hazardous Locations rating in Canada (construction with OS Option) | Class I Div. 2 Groups A , B, C, D, Class II Div. 2 Groups F, G, Class III, T4 | Ex eb mb [ib] IIC T4 | | Hazardous Locations rating in U.S.A (construction with OS Option) | Class I Div. 2 Groups A , B, C, D, Class II Div. 2 Groups F, G, Class III, T4 | Class I, Zone I, AEx eb mb [ib] IIC T4 | | IECEx:: | Ex eb mb [ib] IIC T4 Gb | Ex tb IIIC T135 deg C Db | Ta = -(1) deg. C to -(2) deg C | (1) -60 deg. C or -50 deg. C depending on enclosure type | (2) +15 deg. C, +20 deg. C, +25 deg. C, +30 deg. C, +35 deg. C, +40 deg. C, +45 deg. C, +50 deg. C, +55 deg. C depending on ambient temperature/relay current rating table in the product description. | | ATEX: | II 2(2) GD | Ex eb mb [ib] IIC T4 Gb | Ex tb IIIC T135 deg C Db | Ta = -(1) deg. C to -(2) deg C | (1) -60 deg. C or -50 deg. C depending on enclosure type | ( 2) +15 deg. C, +20 deg. C, +25 deg. C, +30 deg. C, +35 deg. C, +40 deg. C, +45 deg. C, +50 deg. C, +55 deg. C depending on ambient temperature/relay current rating table in the product description. | |
Applicable Standards
IEC 60079-0: 2011, IEC 60079-7: 2006-07, IEC 60079-11: 2011, IEC 60079-18: 2008, IEC 60529: 2013, NEMA 250: 2008,
ANSI/ISA 12.12.01-01: 2012, ANSI/UL 50 12th Edition, ANSI/UL 50E: Ist Edition, ANSI/UL 60079-0: 6th Edition, ANSI/UL 60079-7: 4th Edition, ANSI/UL 60079-11: 6th Edition, ANSI/UL 60079-18: 3rd Edition, ANSI UL 60079-31 2009, ANSI/UL 61010: 3rd Edition
CAN/CSA C22.2 No. 0-10: 2010, CAN/CSA C22.2 No. 0.4-04: 2013, CAS C22.2 No. 25-1966: 2009, CSA C22.2 No. 97.1-07: 2012, CSA C22.2 No. 94.2-07: 2012
CAN/CSA C22.2 No. 130-03: 2013, CSA C22.2 No. 213-M1987: 2013, CAN/CSA C22.2 No. 60079-0:2011, CAN/CSA C22.2 No. 60079-7: 2012, CAN CSA C22.2 No. E60079-11: 2002, CAN/CSA C22.2 No. 60079-18: 2012, CAN/CSA C22.2 No. 60079-31: 2012, CAN CSA C22.2 No. 60529-05: 2010, CAN/CSA C22.2 No. 61010-1: 2012
CSA 2258 02, CSA 2258 82