The system consists of Local Sensor, Main Alarm Panel, Horn & Rotating Light and I.S. circuit Safety Barrier (in case utilized in hazardous areas). When the magnetic float moves upward to the alarm level, the hermetically sealed magnetic reed switch within the stem will be opened and will initiates an alarm. When the magnetic float moves down to the range of normal condition, the reed switch will be closed (non-alarm position) and alarm will be deactivated., 1. Local Sensor of High Level Alarm System (SI-RS-HL) or Overfill Alarm System (SI-RS-OF): This system generates signals if the level of cargo reaches 95% (HIGH LEVEL ALARM) or 98%(OVERFILL ALARM) of a tank capacity by being installed at the upper part of a cargo tank., 2. Local sensor of High Level & Overfill Alarm System (SI-RS-H0): This system is installed at the top of the cargo tank, and if the capacity of the tank goes up to 95% then the alarm makes a warning. And if the High level alarm reaches to 98%, then Overfill alarm makes a warning., 3. Alarm Unit for Remote High Level and Overfill Alarm Monitoring: It provides visible and audible alarm by receiving high level alarm or overfill alarm signals from a local sensor., 3. Horn & Rotating Light: A device generating alarm lamp and alarm signal with supplying level alarm signal of cargo tanks., 4. Safety Barrier: For a local sensor installed in a hazardous area,

Product Ratings
Product Ratings

1. Local Sensor of High Level Alarm System (SI-RS-HL) or Overfill Alarm System (SI-RS-OF) | - Detection Unit: Magnetic float/Reed switch | - Output: Dry contact | - Accuracy: 3mm on level rise or fall | - Max. Working Temp.: -196 degC to 100 degC | - Max. Working Press: 10Kg/cm2 | - Specific Gravity: Min. 0.40 over | - Protection: IP68 | - Material: SUS 316 or Titanium for Float, SUS 304 or 316 for others | 2. Local sensor of High Level & Overfill Alarm System (SI-RS-H0) | - Detection Unit: Magnetic float 2 sets/Reed switch 2 sets | - Output: Dry contact | - Accuracy: 3mm on level rise or fall | - Max. Working Temp.: -196 degC to 100 degC | - Max. Working Press: 10Kg/cm2 | - Specific Gravity: Min. 0.40 over | - Protection: IP68 | - Material: SUS 316 or Titanium for Float, SUS 304 or 316 for others | 3. Alarm Unit for Remote High Level and Overfill Alarm Monitoring (SI-LAS-AU16) | - Power source: DC24V | - Power Consumption: Approximately 0.5VA | - Ambient Temperature: -30 degC to 70 degC | - Output Max. drivel 150mA per channel | - 16 Channel LED Display | - 2 wire communication | 4. Horn & Rotating Light (SED-WS-220 series) | - Power source: AC220V | - Power consumption: 15W | - Sound level: 115dB | - Protection: IP68 | - Color: Red (High level), Yellow (Overfill) | 5. Safety Barrier (D1030S, D1030D) | - Power source: DC24V (20 to 30V) | - Power consumption: 2.6W for 2 channels, 2.2W for 1 channel | - Isolation (test voltage): 1.5kV for I.S. In/Out, I.S. In/Supply, Out/Supply & Out/Out | - Input switching current levels: On above 2.1mA, Off below 1.2mA | - Switching current: Approximately, 1.65mA with 0.2mA hysteresis | - Fault current levels: Open fault below 0.2mA, Short fault above 6.8mA | - Input equivalent source: 8V 1kOhm typical (8V no load 8mA short circuit) | - Output: Voltage free SPDT relay contact | - Contact rating: 2A 250V 100VA or 2A 250V 80W (resistive load) | - Response tie: 20ms | - Frequency response 10Hz max.

Product Standards
Applicable Standards

IACS UR E10 (2014 edition)