RSX: 3-1, 3-2, 5-1, 5-2, 8-1, 8-2, 10-1, 10-2, 15-2
Electric Cables and Accessories
<p>Shipboard Electric Cables and Accessories</p> /url1
Heat Trace Cable & Tapes
RSX: 3-1, 3-2, 5-1, 5-2, 8-1, 8-2, 10-1, 10-2, 15-2
Product Description
Self-Regulating Heating Cable. For foundation heating use Termination kit FHT1-R-10, otherwise HS-PBSX-HD, HS-ET-6C-HD, TBX, ET, PETK-1, SCTK-1, SK-SX, PCA or ECA Power Connection Kits are required.
Product Ratings
Supply Voltage: 120 or 208-240 Vac; | Max Exposure Temperature: 185F (85C) Continuous Power-off; | Max Maintenance Temperature: 150F ( 65C); | T-Rating: 10-2-FOJ, 15-2 FOJ: T5 212F (100C); | T-Rating: 15-2-OJ: T4 248 F (120C); | For insulated externally heated surface, lower T-class and/or maximum surface temperature T systems may be obtained by stabilized design of a trace heating system using methods described in EN-IEC 60079-30-2 clause 6, made under Thermons responsibility. | Hazardous Locations Classification: Class I, Division 2, Groups B, C, and D; Class II, Division 2, Group F & G; Class III, Divisions 1 & 2; Class I, Zones 1 & 2, AExeII.
Applicable Standards
FM Approval Project ID: 3004777 (16 Apr 2004, revised 10 Feb 2012)
FM Approval Project ID: 3004777 (16 Apr 2004, revised 10 Feb 2012)
NA