Skip to main content

Motor controller for marine electric motor starter

Product Category Icon
Product Category:
Instrumentation and Automation

Product type  Icon
Product Type:
Programmable Electronic System

Product name
Product Name:
Motor controller for marine electric motor starter
Product Description
Product Description

A.Type : Motor controller for marine electric motor starter
SMC-501E/501EH, SMC-502E/502EH, SMC-503E/503EH, SMC-504E/504EH and SMC-505E/505EH
B.Technical specifications:
1.Input Power Source:
- Voltage rating: AC 22V 50/60Hz
- Voltage variation: AC 22V ±20%
- Power consumtion: 20VA (max)
2.Rating of control relay for electromagnetic contactor:
- Maximum rating: 264 Vac, 5A (power factor 1.0)
- Life expectancy: Mechanical life-30,000,000 cycles / Electrical life-100,000 cycles
3.Rating of control relay for signal interface: 250Vac, 5 A (power factor 1.0)
4.Timer Characteristic:
- Accuracy (-10°C<TA<45°C): less than ±1%
- Accuracy (-10°C<TA<-20°C),(45°C<TA<55°C): less than ±5%
5.Encolsure and terminal bord:
- Material: PC (Flame retardant) UL94 V-O/TRIREX3025G10/G/F (Reinforced)
6.IP Grade: IP 65(Front).
C.Control function and specification of display:
1.Type SMC 501E/501EH:
- Application: Constant Speed (Direct on line start)
- Basic function: Start, Stop, Under Voltage Release UVR (with sequential start function)
- Under Voltage Protection UVP (without sequential start function), Lamp Test LPT
- Additional Function: Heater Control
- Alarm Signals: Power failure, Overloaded
2.Type SMC 502E/502EH:
- Application: Constant Speed (Local / Remote)
- Basic function: Start, Stop, UVR , UVP, LPT
- Additional Function: Heater Control, Remote Control
- Alarm Signals: Power failure, Overloaded
3.Type SMC 503E/503EH:
- Application: Reversible (FWD / REV)
- Basic function: Start, Stop, UVR , UVP, LPT, Reversible (FWD / REV), Interval Timer
- Additional Function: Heater Control
- Alarm Signals: Power failure, Overloaded
4.Type SMC 504E/504EH:
- Application: 2 Speed (High / Low)
- Basic function: Start, Stop, UVR , UVP, LPT, 2 Speed (High / Low), Interval Timer
- Additional Function: Heater Control,
- Alarm Signals: Power failure, Overloaded
5.Type SMC 505E/505EH:
- Application: Automatic change over
- Basic function: Start, Stop, Automatic change over, Chattering timer, Parallel run,
- Pressure build-up, Stand-by, UVR , UVP, LPT, Self-diagnosis
- Additional Function: Heater Control, Stand-by, Parallel run
- Alarm Signals: Power failure, Overloaded, CPU fail, Stand-by started, LPS,
Abnormal stop, Low Pressure Alarm.

Product Ratings
Product Ratings

Not Available / To be Updated

Product Standards
Applicable Standards

Not Available / To be Updated