FR Series, FRS Series, FSC Series, FS Series, Cable and pipe Transits
Electric Cables and Accessories
<p>Shipboard Electric Cables and Accessories</p> /url1
Cable and Pipe Transits
FR Series, FRS Series, FSC Series, FS Series
Product Description
Modular cable transit system consisting of steel frames or plugs in combination with insert blocks, made of halogen-free EPDM, as well as compression units., , 1. Type FR for A60 single or multi cable penetration on deck & bulkhead, FR-50:, Steel Coaming Size: d60mm x 74mm (Deep), thickness 4.5mm; Maximum ratio of cable occupation: 7%; Maximum cable outside diameter: 13mm, FR-200:, Steel Coaming Size: d219mm x 80mm (Deep), thickness 9mm; Maximum ratio of cable occupation: 10%; Maximum cable outside diameter: 38mm, 2. Type FRS for A60 single cable penetration on deck & bulkhead, FRS-25:, Steel Coaming Size: d32mm x 35mm (Deep), thickness 3mm; Maximum ratio of cable occupation: 10%; Maximum cable outside diameter: 8mm, FRS-43:, Steel Coaming Size: d52mm x 65mm (Deep), thickness 4mm; Maximum ratio of cable occupation: 29%; Maximum cable outside diameter: 23mm, 3. Type FSC & FS for A60 multi cable penetration on deck & bulkhead:, FSC & FS-8+8*6, Steel Coaming Size: 793mm (L) x 593mm (W) x 60mm (D), thickness 10mm; Maximum ratio of cable occupation: 33%; Maximum cable outside diameter: 68mm, FSC & FS-2*1:, Steel Coaming Size: 140.5mm (L) x 121mm (W) x 60mm (D), thickness 10mm; Maximum ratio of cable occupation: 9%; Maximum cable outside diameter: 33mm, 4. Type FR for A0 single or multi cable penetration on deck & bulkhead, FR-50:, Steel Coaming Size: d60mm x 74mm (Deep), thickness 4.5mm; Maximum ratio of cable occupation: 10%; Maximum cable outside diameter: 15.7mm, FR-200:, Steel Coaming Size: d219mm x 80mm (Deep), thickness 9mm; Maximum ratio of cable occupation: 22%; Maximum cable outside diameter: 50mm, 5. Type FRS for A0 single cable penetration on deck & bulkhead, FRS-25:, Steel Coaming Size: d32mm x 35mm (Deep), thickness 3mm; Maximum ratio of cable occupation: 11%; Maximum cable outside diameter: 8.3mm, FRS-43:, Steel Coaming Size: d52mm x 65mm (Deep), thickness 4mm; Maximum ratio of cable occupation: 29%; Maximum cable outside diameter: 23.1mm, 6. Type FSC & FS for A0 multi cable penetration on deck & bulkhead:, FSC & FS-8+8*6, Steel Coaming Size: 793mm (L) x 593mm (W) x 60mm (D), thickness 10mm; Maximum ratio of cable occupation: 42%; Maximum cable outside diameter: 82mm, FSC & FS-2*1:, Steel Coaming Size: 140.5mm (L) x 121mm (W) x 60mm (D), thickness 10mm; Maximum ratio of cable occupation: 20%; Maximum cable outside diameter: 33mm
Product Ratings
Cable transit system for A-60 & A-0 bulkhead / deck penetrations | Watertight test: 0.4 Mpa for 60 minutes; | Gastight test: 0.4 Mpa for 60 minutes.
Applicable Standards
SOLAS (Consolidated Edition 2014), as amended, Chapter II-2, Regulation 9.3.1; 2010 FTP Code (2012 Edition), Annex 1, Part 3 Appendix 2 A.IV "Cable Transits"