Skip to main content

Ex RC 12; Ex RC 13,5; Ex RC 15; Ex RC 23; Ex RC 60; Ex RC 25…

Product Category Icon
Product Category:
Instrumentation and Automation

Product type  Icon
Product Type:
Misc. Detectors

Product name
Product Name:
Ex RC 12; Ex RC 13,5; Ex RC 15; Ex RC 23; Ex RC 60; Ex RC 2580 Ex RC M 14; Ex RC M 20; Ex RC Si M 30; Ex RC Si 56
Product Description
Product Description

The magnetic sensors are actuated by an permanent magnet, entering their proximity without any physical contact.
Switching system: Reed Contacts
Ex RC 12; Ex RC 13,5; Ex RC 15
Contact types: 1NC,1NO or 1CO contact
Switching frequency: max . 50Hz
Switching Voltage: 250 V
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC 23
Contact types: 1CO contact
Switching frequency: max . 50Hz
Switching Voltage: max. 90 VAC/ 125 VDC
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC 60
Contact types: 1NO, 1CO or bistable contact
Switching frequency: max . 50Hz
Switching Voltage: 250 V
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC 2580
Contact types: 1CO contact
Utilisation Category: AC-12; DC-12
Switching Voltage: 250 V
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC M 14
Contact types: 1NO or 1CO contact
Switching frequency: max . 50Hz
Switching Voltage: 250 V
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC M 20
Contact types: 1NO or 1CO contact, bistable or bistable CO contact
Switching frequency: max . 50Hz
Switching Voltage: 250 V
Explosion protection: II2G Ex mb IIC T6 Gb/ II2D Ex mb IIIC T80°C Db IP67 as per certificate DMT 01 ATEX E 058 X
Ex RC Si M 30
Contact types: 1NC/1NO or 2 NC contacts
Switching frequency: max . 5Hz
Switching Voltage: max. 30 VDC
Explosion protection: II 2G Ex mb IIC T6 Gb / II 2D Ex mb IIIC T80°C Db IP67 as per certificate PTB 05 ATEX 2024X
Ex RC Si 56
Contact types: 1NC/1NO or 2 NC contacts
Switching frequency: max . 5Hz
Switching Voltage: max. 30 VDC
Explosion protection: II 2G Ex mb IIC T6/T5 Gb; II 2D Ex mb IIIC T80°C / T95°C Db IP67 as per certificate PTB 08 ATEX 2027X

Product Ratings
Product Ratings

Not Available / To be Updated

Product Standards
Applicable Standards

Not Available / To be Updated

Similar Products